The design of 2/8-type high-pressure cell applied to in situ neutron diffraction
Xiang Chun-Jiang1, Hu Qi-Wei1, Wang Qiang1, Xie Lei2, Chen Xi-Ping2, Fang Lei-Ming2, †, He Duan-Wei1, ‡
Institute of Atomic and Molecular Physics, Sichuan University, Chengdu 610065, China
Key Laboratory of Neutron Physics and Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621999, China

 

† Corresponding author. E-mail: flmyaya2008@163.com duanweihe@scu.edu.cn

Project supported by the National Natural Science Foundation of China (Grant No. 11427810), the National Key Research and Development Program of China (Grant No. 2016YFA0401503), and the Project for Science and Technology Plan of Sichuan Province, China (Grant No. 2015GZ0053).

Abstract

The DIA-type Kawai cell possesses a larger volume and a quasi-hydrostatic pressure environment and has been widely used in materials’ synthesis and x-ray diffraction experiments. However, few high-pressure in situ neutron diffraction experiments were performed in the DIA-type Kawai cell because there is no wide window for neutron diffraction and the second-stage anvils and guild block material attenuates the neutron signal significantly. In this work, we tentatively modified the normal DIA-type Kawai cell (MA 2-6-8) into a MA 2-8 mode by removing the six first-stage tungsten carbide anvils. As a consequence, the eight tungsten carbide anvils (Kawai cell) are directly driven by the guide blocks. The results of ex situ and in situ pressure calibration show that the cell pressure can reach 5 GPa with small truncation edge lengths (TEL) of 3 mm even at the load of 300 kN. It suggests that this MA 2-8 cell may open a new way for high-pressure and high-temperature in situ neutron diffraction.

1. Introduction

With respect to high-pressure in situ x-ray diffraction, high-pressure in situ neutron diffraction (HPND) provides a unique tool at extreme condition for probing crystallographic structures of the many important materials containing light atoms including H(D), Be, B11, C, and N,[16] and giving structural information of liquid and glassy materials.[710] Besides, HPND provides indispensable information for understanding the chemical composition, stability, and optical properties.[11] However, in contrast with synchrotron sources, the intrinsically weak sources of neutron radiation available, reactor or spallation-based sources, demand large sample volume, leading to the compromise between data quality and maximum attainable pressures. According to experience and some semi-empirical considerations, the maximum achievable pressure Pmax is approximately proportional to an inverse power of volume V, i.e. , with .[12] This implies that the pressure limitation will sharply reduce if the sample volume increases. Therefore, the pressure had been limited in the kbar range in a long time since the HPND technology was employed.[13,14] High-pressure technology also has important implications for other disciplines. In the field of materials science, high pressure annealing significantly reduced the heat treatment temperature as for of thin-film material.[15]

During the past years, many high-pressure devices had been developed for neutron diffraction experiments, such as McWhan-type cylinder-piston cell[13] and opposed-anvils cell.[16,17] Nowadays the Paris-Edinburgh press equipped with the toroidal opposed cupped anvils has been widely employed in the HPND experiments.[12,18] A key feature of PE press is their small volume and “compactness”, i.e. their high capacity compared to their mass. A V3 (VX3) press has a capacity of 250 tones but only a mass of 50 kg,[19] which is crucial for neutron diffraction because of the very limited space in the neutron beam-line. This high-pressure device generates a wide range of pressures up to 10 GPa with single toroid tungsten carbide anvils and to 25 GPa with double toroid sintered diamond anvils.[18,20] However, this uniaxial-loaded opposed-anvil cell usually generates large stress due to the absence of liquid transmitting medium.[18] Furthermore, because of the limitation of the cell volume improvement it is impossible for high-temperature experiments, which usually requires a mass of ceramic pressure-transmitting medium working as a thermal and electrical insulator. Alternatively, multi-anvil (MA) cell, such as cubic anvil and octahedral anvil cell, possesses a larger cell volume and a quasi-hydrostatic pressure environment and has been widely used in diamond synthesis[21] and x-ray diffraction experiments.[22] However, because of the limited space at neutron diffraction beam-line many large volume apparatuses are not suitable choices. The uniaxial-loading DIA-type apparatus has a smaller volume and the uniaxial-loading is transferred to the six-anvil by upper and lower guild blocks. In order to further enhance the cell pressure, an assembly of eight cubic anvils of tungsten carbide or sintered diamond with the octahedral pressure medium and gaskets, the Kawai cell, is squeezed by the six first-stage anvils.[21] This MA 2–6-8 type apparatus has the advantage of producing homogeneous pressures at larger sample volumes over competitive high-pressure devices such as the diamond anvil cell (DAC).[2325] The attainable pressure and temperature can reach 83.7 GPa and 1500 K using sintered diamond as the second-stage anvil.[26]

Unfortunately, few high-pressure in situ neutron diffraction experiments were performed in the DIA-type Kawai cell. Although this guide block system is a simple and effective way to produce high pressure, there is no wide window for neutron diffraction and the second-stage anvils and guild block material attenuates the neutron signal significantly. In this work, in order to obtain larger space for angle-dispersion neutron diffraction, we tentatively modified the DIA-type Kawai cell (MA 2–6-8) into MA 2/8, suggesting that the six first-stage anvils are removed and the assembly of eight cubic anvils of tungsten carbide is driven by the guide blocks directly. Then we performed high-pressure in situ neutron diffraction using the apparatus based on the neutron scattering facility (Fenghuang) of China Mianyang Research Reactor (CMRR). The pressure can reach 5 GPa with truncation edge lengths 3 mm at the load of 300 kN.

2. Design apparatus

The MA2-8 cell is mainly divided into two parts, guide blocks and the gasket-sample assembly. Figure 1 shows the major parts of the 2/8-type high pressure apparatus: the guild block, the second-stage anvil, and the gasket-sample assembly. Figure 1(a) is an overall diagram of the 2/8-type cell. The uniaxial-loading is transferred into axles through the interaction of the guide blocks and the secondary pressurizing unit. There is no contact between the grooved bottom of the guide block and the secondary pressurizing unit during the experiment. The secondary pressurizing unit consists of eight second-stage tungsten carbide anvils, twelve gaskets, and an octahedron pressure medium with sample. The fixing of the device is accomplished using four Teflon nuts, which are transparent for neutron. The neutron beam is directed horizontally between the gap of second-stage anvils and then transmits through the gasket and sample (Fig. 1(b)).

Fig. 1. (a) Overall diagram of the modified DIA-type Kawai cell. (b) The mode of high pressure neutron diffraction.

Figure 2(a) shows the optimization of the second-stage anvils. The second-stage anvil has a large truncation edge length (TEL) and a small TEL on the opposite sides of the body diagonal. The small TEL assembled with pressure medium and gaskets is used to generate high pressure. The large TEL is used to fit the sliding surface of guide block groove. We tested pressure generation using the second-stage anvil with edge length of the cubic anvil of 10 mm and 12 mm. But it failed no more than at 200 kN due to the rupture of the anvil bevels. To solve this problem, we made some improvements to the apparatus. The volume of the secondary anvil was increased, the edge length of the cubic anvil increased to 14 mm. The large TEL increases from 7 mm to 10 mm and the area is increased to twice as before. The stress at the truncation is inversely proportional to the area. Therefore, the stress of the large truncation is reduced under the same loading, leading to the expansion the range of loading. Meanwhile, the large TEL is machined to a 0.6 rounded corner. This makes it easier to slide between the guild block and the second-stage anvils.

Fig. 2. (a) The optimization of the second-stage anvils. (b) The cross section of the octahedron transmitting pressure medium.

The octahedral edge length (OEL) of the pressure medium and the size of the TEL are the key points determining the volume of the sample and limitation of the cell pressure.[27] We design two kinds of small TEL, 1.5 mm and 3 mm. Then we used an empirical method called “limiting compression volume ratio φ” to determine the size of OEL.[28] For small TELs of 1.5 mm and 3 mm, the corresponding OELs are 5.7 mm and 8.2 mm, respectively. The pressure media were octahedral MgO, which is a commonly used pressure medium owing to its large bulk modulus.[29,30] For the gaskets, we used raw pyrophyllite with a thickness of 2.45 mm (T) and a width of 2.94 mm (W) for a TEL of 3.0 mm, while T = 1.98 mm and W = 2.37 mm were used for a TEL of 1.5 mm. Figure 2(b) shows the cross-section of the 5.7/1.5 assembly.

3. Pressure calibration experiment

A series of pressure calibration experiments were carried out for the 2/8-type cell, including resistance calibration and in situ neutron diffraction. The ex situ pressure generation tests of the 2/8-type cell were carried out using the 300 kN servo-hydraulic press installed in the lab of High-pressure Science and Technology, Sichuan University. The machined octahedron transmitting pressure medium was cut in half, and the pressure maker was put inside it. A bit of the pressure maker was placed in the middle of the pressure media for pressure evaluation. Copper foil (0.1 mm thickness) was used as a wire, connected to the second-stage anvils and pressure maker. The assembled two-stage pressurization unit was put into the upper guild block and lower guild block to carry out a pressure calibration experiment. The phase transitions of ZnTe at 5 GPa was used as pressure fixed points to determine generated pressures, a piece of ZnTe single crystal was crushed into coarse-grained powder (grain size of ), which was used as the calibrant. Copper rods (0.8 mm in diameter) were used as electrodes and the calibrant was put in between the electrodes. The transition was also detected by two-wire electric resistance measurements.

The high-pressure in situ neutron diffraction experiments are performed on a high-pressure neutron diffraction spectrometer (Fenghuang) at the China Mianyang Research Reactor (CMRR). The monochrome beam with a wavelength of 1.59 Å was adopted for all neutron diffraction patterns. The detector consists of 70 3He counting tubes, scanning the diffraction angle from 8° to 172°. The size of incident neutron beam at sample position is about 2 × 3 cm2.[31] The loading force is generated by the 2000 kN Paris-Edinburgh press.[32] An iron cylinder (99.99%, Alfa Aesar, US) with a size of was used as a sample. The sample pressure was continuously monitored in situ by using the equation of state (EOS) of crystalline Fe. We used the third-order Birch–Murnaghan isothermal EOS to calculate the sample pressure:[29] where , , and V0 represent the bulk modulus, its derivative with respect to pressure, and the unit cell volume under ambient conditions, respectively. The pressures of Fe a-phase were obtained from the third-order Birch–Murnaghan equation using the measured , where GPa, and obtained from the ultrasonic velocity measurement.[30] The corresponding cell volume V under different pressure conditions can be obtained via Rietveld refinements.

4. Results and discussion

Figure 3 shows the resistance of ZnTe associated with press loading. The experiment was performed using WC anvils with a TEL of 1.5 mm at room temperature. The edge length of the corresponding octahedral pressure medium is 5.7 mm. The phase transition occurs at 5 GPa with the resistance decreasing rapidly. The loading forces measured in the three experiments are 224 kN, 246 kN, and 220 kN, respectively. The loading value 230 kN is the average value of the three experiments, that is to say, the internal pressure reaches 5 GPa at 230 kN. Taking the average value as the reference value, the relative errors are calculated to be 2.6%, 7.0%, and 4.3%, respectively. In the resistance calibration experiments, the average value of the relative error is 4.6%.

Fig. 3. ZnTe pressure calibration results and fitted curves at room temperature. Pressure generation is based on 5.7/1.5 assembly using 14-mm tungsten carbide cubes as second-anvil.

Figure 4 shows neutron diffraction patterns collected at different loads. The curve (black) represents the neutron patterns collected at ambient condition. Only the (110) plane and (211) plane of Fe can be indexed because of the stronger peak intensity of tungsten carbide anvils and the MgO transmitting pressure medium. The curves (red) and (blue) in Fig. 4 are the neutron diffraction patterns collected at 200 kN and 300 kN, respectively. With pressure increasing, (110) and (211) all shift to higher degree and the intensity weakens due to the decreases of the gasket thickness. This high-pressure in situ neutron diffraction is performed using WC anvils with a TEL of 3.0 mm at room temperature. The OEL of the corresponding octahedral pressure medium is 8.2 mm. The thickness of the gasket was 2.4 mm before the experiment, after a loading of 300 kN, the thickness of the gasket was 1.3 mm. The (211) peak is shifted to a higher degree and hides in the peak of tungsten carbide. The (110) peak still can be used for pressure calibration, and the unit-cell volume of Fe can be obtained at different pressures. The cell volume at room pressure (V0) is 23.57 Å3 and the cell volumes are 23.10 Å3 and 22.96 Å3 at 200 kN and 300 kN, respectively. The cell pressure can be calculated using the EOS of Fe. Under loading of 200 kN and 300 kN, the achieved sample pressure is 3.5 GPa and 4.5 GPa, respectively.

Fig. 4. The neutron diffraction patterns of iron collected under ambient conditions (black curve), 200 kN (red curve), 300 kN (blue curve), respectively. The black rhombus marks the peak of Fe. Other peaks are also shown, including guide block and anvils made of tungsten carbide and MgO pressure medium.

Figure 5 shows the pressure calibration curve obtained based on the resistance calibration of the phase transition and the neutron diffraction of Fe. A pressure of 5 GPa can be achieved at 230 kN using a 5.7/1.5 assembly. Compared with the 8.2/3 assembly, the area is reduced with the reduction of the TEL, so the same loading can produce higher pressure. The pressure calibration curve is nearly linear, which means that 5 GPa is not the limited pressure and can be further expanded by further optimization.

Fig. 5. Pressure calibration curves obtained at room temperature. High pressure calibration curves using 8.2/3 are shown (black line). The red points represent the pressure calibration results using 5.7/1.5 assembly.
5. Conclusion

We have developed a new DIA type Kawai cell (2/8-type cell) for high-pressure in situ neutron diffraction. This device mainly consists of upper and lower guide blocks, and a two-stage pressurization unit that is composed of second-stage anvils, a pressure medium, and twelve gaskets. The maximum pressure that is achieved by this device is 5 GPa via the pressure calibration of resistance. The device has also been tested for high pressure in situ neutron diffraction. A pressure of 4.5 GPa is achieved using an 8.2/3 assembly at the loading 300 kN. Compared with the traditional PE press for in situ neutron diffraction, the new DIA type Kawai cell has a significant advantage in heating. This Kawai cell can provide steady internal heating rather than applying power directly to the anvil as in the PE press. In the future, the pressure range could be further expanded by replacing tungsten carbide anvil with polycrystalline diamond anvil. We will do high temperature and high pressure experiments, which will promote the progress in high pressure and high temperature in situ neutron diffraction.

Reference
[1] Lokshin K A Zhao Y He D Mao W L Mao H K Hemley R J Lobanov M V Greenblatt M 2004 Phys. Rev. Lett. 93 125503
[2] Finney J L Hallbrucker A Kohl I Soper A K Bowron D T 2002 Phys. Rev. Lett. 88 225503
[3] Klotz S Bove L E Strässle T Hansen T C Saitta A M 2009 Nat. Mater. 8 405
[4] Nelmes R J Mcmahon M I Wright N G Allan D R Loveday J S 1993 Phys. Rev. B. 47 7668
[5] Maynardcasely H E Bull C L Guthrie M Loa I Mcmahon M I Gregoryanz E Nelmes R J Loveday J S 2010 A. J. Chem. Phys. 133 064504
[6] Wilson C W Bull C L Stinton G Loveday J S 2012 J. Chem. Phys. 136 094506
[7] Klotz S Hamel G Loveday J S Nelmes R J Guthrie M Soper A K 2002 Phys. Rev. Lett. 89 285502
[8] Wilding M Guthrie M Bull C L Tucker M G Mcmillan P F 2008 J. Phys. Condens Mat. 20 244122
[9] Bouzid A Pizzey K J Zeidler A Ori G Boero M Massobrio C Klotz S Fischer H E Bull C L Salmon P S 2016 Phys. Rev. B 93 014202
[10] Zeidler A Wezka K Rowlands R F Whittaker D A Salmon P S Polidori A Drewitt J W Klotz S Fischer H E Wilding M C 2014 Phys. Rev. Lett. 113 135501
[11] Huang D Liu H Hou M Q Xie M Y Lu Y F Liu L Yi L Cui Y J Li Y Deng L W Duo J G 2017 Chin. Phys. B. 26 089101
[12] Stephen Hull 2015 Techniques in High Pressure Neutron Scattering 56 104 by Stefan Klotz, Contemporary Physics
[13] McWhan D B Bloch D Parisot G 1974 Rev. Sci. Instrum. 45 643
[14] Vettier C Mcwhan D B Blount E I Shirane G 1977 Phys. Rev. Letters. 39 1028
[15] Guo H L Yang H Y Tang H F 2013 Acta. Phys. Sinica. 62 130704 in China
[16] Boehler R Guthrie M Molaison J J Santos A M D Sinogeikin S Machida S Pradhan N Tulk C A 1976 Rev. Sci. Instrum. 47 296
[17] Boehler R Molaison J J Haberl B 2017 Rev. Sci. Instrum. 88 083905
[18] Bull C L Funnell N P Tucker M G Hull S Francis D J Marshall W G 2016 High Press. Res. 36 493
[19] Klotz S Hamel G Frelat J 2004 High Press. Res. 24 219
[20] Klotz S Besson J M Hamel G Nelmes R J Loveday J S Marshall W G Wilson R M 1995 Appl. Phys. Lett. 66 1735
[21] Kawai N Endo S 1970 Rev. Sci. Instrum. 41 1178
[22] Inoue K Asada T 1973 Jpn. J. Appl. Phys. 12 1786
[23] Taniguchi T Akaishi M Kanke Y Yamaoka S 2004 Rev. Sci. Instrum. 75 1956
[24] Wang W Sokolov D A Huxley A D Kamenev K V 2011 Rev. Sci. Instrum. 82 587
[25] Yang F Kaplonski J Unruh T Mamontov E Meyer A 2011 Rev. Sci. Instrum. 82 012102
[26] Kunimoto T Irifune T 2010 J. Phys. Conf. Series IOP Publishing 215 012190
[27] Frost D.J. Poe B.T. Trønnes R.G. Liebske C. Duba A. Rubie D.C. Physics of the Earth and Planetary Interiors 143 507
[28] He F He D W Ma Y G Yan X Z Liu F M Wang Y K Liu J Kou Z L 2015 Chin. J. High Press. Physics 29 3
[29] Stavrou E Zaug J M Bastea S Crowhurst J C 2016 J. Appl. Phys. 119 134111
[30] Singh A K Jain A Liermann H P Saxena S K 2006 J. Phys. & Chem. Solids 67 2197
[31] Sun G Zhang C Bo C Jian G Peng S 2016 Neutron News 27 21
[32] Shi Y Chen X P Xie L Sun G A Fang L M 2019 Acta Phys. Sin. 68 116101